 |
Your present position: Technology >> Floor coating system design notes |
Floor coating system design notes
Industrial design of the floor - the main factor in the decision:
Investment and performance analysis of the comparison:
Design is a vital link in the design of an adverse result in the issue, and reasonable design can avoid the problem. People often on the floor of the industrial design to give sufficient attention, usually in the new project-type technical requirements and project budget to include them in the book, "interior decoration", almost always have to wait until the whole structure or after the completion of the concrete slab poured Start thinking about this issue, and into the projects and maintenance work, often on the floor and the program is to install equipment in the factory or after the trial to start thinking about. This concept may be related to investment in infrastructure, but if the idea due to underestimate the problems arising from the design on the ground, thus causing delays in production losses, on this issue should be taken seriously. The basic design based on the use of end-user requirements; expected or actual on-site conditions: it is new construction or repair and maintenance works.
Construction cycle can not meet the set-top plans:
In any project, for the user, an important goal is to shorten the project cycle. Whether new or renovation project, financial requirements are put into operation as soon as possible. This means that in the early stage of the project, said people need to clearly points clear and feasible engineering and construction cycle time. Only by following the requirements of the floor system can be considered: coated in fresh or direct surface cement age construction; the whole system can quickly complete the construction, coating each time interval; surface curing speed, A short period of time to bear traffic. Kim profits on the floor to prevent the technology can be avoided due to the wet surface-coating damage caused when the cement in the category of brushing the surface of active matrix resin material, material moisture content not to be more than 6%. Otherwise they would undermine the coating. The initial construction of a small bubble in a short period of time after there will be a gradual development and expansion, so that the final coating completely off. This is called "bubble infiltration" of the damage must be avoided.
The use of the installation / construction to minimize the risk:
In order to ensure the chosen product to really branch operation in accordance with the requirements for construction, and so the need for China to achieve the performance requirements of the floor system provides the best quality of the preservation of evidence: the pre-project diagnosis; in the construction process and the completion of the The assessment on the floor.
Design life:
This is probably the most basic means of the standard, but also in the selection of the first floor when asked to. The plant is designed life span of the number - 2, 5, 10 or 20 years? On a regular basis to maintain the feasibility and need? The choice of programs on the ground must meet the expected design life expectations or maintenance-free period.
Use:
During the construction, production, transformation and maintenance on the ground to impose the static and dynamic load required to be taken into account. On the one hand painted on the ground must be able to bear the required load, and in the other hand, it must be remembered that only in the basement (such as concrete or cement mortar board structure of the surface layer) to achieve the same request on its coating should be able to play There are roles. In some cases, the cantilever through carbon fiber paste to step up.
Seam construction:
There is little movement of joints, such as the construction joint, and so on, the profits in gold on the ground outside the system, the rationale of the program, you can adopt a flexible cover seal coating approach to deal with. In the basement soil mixing board in the structure of the existence of mobile joints [isolation or joints must be set aside on the floor. At the same time, we also suggested that the ramp of the highest walls and equipment and set up around the joints mobile.
Surface design:
Easy to maintain the floor, in addition to seamless protection of concrete from corrosive liquid and mechanical wear, but also against the need to meet hygiene and safety requirements such as durability, and they provide a crisp and friendly atmosphere. Architects and design of the customer is always asked to consider the function subjectively, and the two standards. By using a special construction method, different requirements can be met. The laying of the details
The drainage channels:
In accordance with the layout of the factory, as long as possible, the drainage channels are always designed in the passage outside the area. The floor is large enough to have the slope of the liquid into the tank as soon as possible - and the bed slope usually larger. If you must use the slot, then have to slot grille and side cover fixed given enough attention, because these problems more likely. When there is a serious erosion of the liquid, gold profits in the construction procedure will use the passive tank wall, with enough angle fixed up.
And water-pipe:
People today use steel or polypropylene tank-system, it is important to take measures to ensure the tightness of its outer wall. Information design on the floor
Transport and machinery wear and tear:
Designed to be resistant to consider the impact of wear and tear, and other physical and mechanical requirements. Typically, the most wear occurred in the following areas - Forklift channel, or some of the specific region, the need for special ground handling.
Anti-corrosion chemicals:
Not only have to consider the existence of a single species of plant chemicals on the ground, but also should consider the potential of a chemical reaction, if there are chemicals mixed on the ground, what happens? Splattered or after the evaporation of the most concentrated or dilute the concentration is how much? High temperature to increase regular activity of the chemicals - particularly the strong acid and alkali. Splattered in a number of potential areas such as production, storage and cargo area, the temperature is also an important factor.
Temperature:
The dramatic temperature change is caused by the failure of traditional industries on the floor of the main reasons. Therefore it is very important not only to consider the temperature of the machine operation and production processes of product temperature, but also our neighbors and the temperature. In some regions, often carried out a number of activities, such as high-pressure cooking, cooking, freezing or sterilization, and so on, often in extreme temperatures, so these areas need special handling.
Non-slip:
Pedestrian zone on the extent of anti-skid depending on the requirements of the environment dry humidity, consider the surface of the ground they should pay attention to the requirements of its non-slip, the better. However, the rough surface is very difficult to achieve a clean and sanitary requirements, so they have to strike a balance. Therefore, the proposed root show different design requirements of the non-slip floor, and meet other requirements.
Impact / load points:
In the goods often concentrated in certain areas of the storage or handling cases, such as production lines, storage, loading terminals, and so on, the floor must be suitable for the design of these structures will be working conditions. Equipped with a cargo of trucks, pallets and other objects of the campaign will have a pressure load, in the absence of local capacity to design aside, it is prone to damage. Another important issue is the need to ensure that the resulting stress is not higher than that of the entire system of floor material can bear the pressure.
Health:
Many modern industries, such as: pharmaceuticals, cosmetics, food, beverage, chemical and electronics industry, have the same health requirements of these industries in the manufacturing process are similar to the requirements of "clean room" working environment, such as the ground must be completely clean, there is no Cracks at right angles and corners, easy to clean and meet other requirements, such as anti-corrosion chemicals and armed anti-wear ability.
Impermeable:
Today's environmental requirements must be resistant coating on the ground infiltration to preserve and concrete retaining water from the drip of water and pollutants. In some cases, not only to infiltrate the ground with a chemical used to prevent corrosion of the soaking liquid pollutants, such as: metal processing industry, zinc, the food processing industry (dairy products, meat, vegetables), and cleaning will also get in touch with the Chemicals, such as: cleaner, steam and machinery.
Jumper's ability to crack:
This structure of the load, dynamic load of other objects. The factory, vibration and wear and tear on the passage on the floor what effect? To avoid cracks of the importance of how much? In certain regional projects, such as outdoor parking lot, where corrosive liquids production areas, or "clean room" area, the completion of the floor area must be dynamic ability to crack jumper. Stress or sewing or sewing activities in order to prevent subsequent cracking.
The impact of noise damping:
Industrial oxygen environment are often used on the floor in the hall, corridors, exhibition rooms and sales areas, but here with the traditional standard of industrial floor quite a bit different. And under high load floor, in offices, hospitals, etc. on the floor surface with different relative outside, usually on the floor of the use of a person's walking or standing. For this reason, we recommend the use of flexible floor system, which should have non-slip and comfort features.
Thermal properties:
Users determine the floor at the foot of the well-being is very different and very subjective. In addition to the floor and the room temperature, the thermal conductivity of the floor is the most important factor. Thermal conductivity of the lower value (0.5W/mk), feel, the more obvious. In addition to this indicator, the color in the subjective effects can not be underestimated (the use of warm or cool colors).
UV performance:
Industry as a whole floor of its useful life, should be stable mechanical properties. This needs to determine whether it met on a standard floor is whether the moderate or high degree of ultraviolet stability, in accordance with the use of the case may be, in particular the radiation of high energy ultraviolet radiation resin floor into a powerful role in the destruction, leading to its Faded or performance.
Chair of the roller pressure resistance:
Office chair of the roller diameter is very small, and therefore the floor of a large local load, the load in a chair on the floor have moved an additional pressure. Can only choose to take the test by the load on the floor of the system.
A variety of colors:
Everyone to experience the color and the color of the reflected light to the human body and emotional effects of color harmony in a work environment, there will be conducive to a person's behavior and health, and the color can also be used to distinguish between different regions of the mark Such as traffic or directional area. Shenzhen Jinli Tc purification Technology Co., Ltd. to provide international standard color card.
|